Switch Selection

image.png

Inclusion of Losses

image.png

image.png

image.png

image.png

Solving lossy converters

  1. Draw each subinterval circuit and write $v_L$ and $i_C$

  2. Average: volt-second balance and charge balance and set to 0

  3. Turn each averaged equation into a circuit

    1. KVL equation (volt-second) becomes a series loop carrying $I_L$. Each voltage term is an element in the loop, fixed source, resistor, or dependent voltage source for anything like D’V
    2. KCL equation (charge balance) becomes a node. Each current term is a branch
  4. Merge dependent source pairs into DC tranformers

    1. A dependent voltage source in a loop with coefficient k pairs with a dependent current source at a node with the same coefficient k, and the pair is a 1:k transformer

    2. Input-side transformer ratio

      image.png

  5. Reflect everything onto one side

    1. $n = \frac{\text{turns on side you’re moving to}}{\text{turns on side you’re moving from}}$
    2. resistor → $\times n^2$
    3. voltage source → $\times n$
    4. current source → $\div n$
    5. If transformers are oppositely coupled, invert any sources
  6. Voltage divide to get M(D)